Next day installation

No deposit required

Pay in 3 interest-free

Price match promise

Boiler Advice

F75 Vaillant Fault Code Meaning, Causes and Fixes

F75 Vaillant Fault Code Meaning, Causes and Fixes

What does the Vaillant boiler F75 fault code mean?

The Vaillant F75 error code pertains to the water pressure of the boiler and signifies that the pressure sensor has identified low water pressure. This error may occur due to several factors such as a leak in the system, a defective pressure sensor, or an issue with the filling loop.

Get new boiler quotes online >

You can simply try topping up the pressure yourself and this could fix the issue, however, if the pressure drops rapidly or persists to drop over time, then there are likely other issues that need looking at by a Gas Safe engineer.

Old inefficient boiler causing high gas bills? Read our guide to Vaillant boiler prices here for more information.

What is the Vaillant F75 error code?

If you are wondering what does the f.75 mean on a boiler? The following possible causes of the Vaillant F75 fault, and although the boiler may be operating correctly, F75 fault codes could indicate that something is wrong with either of the following:

Boiler pressure sensor

The boiler pressure sensor is exactly that. it senses how much pressure is in your boiler. If this is faulty you may get the F75 fault code. If both of these issues are the case then you will not be able to fix the problems unless you are a qualified engineer.

The following possible causes of the Vaillant F75 fault are listed in the boiler manual:

A defective water pressure sensor or pump, heating system, too high pressure in the boiler; connect an external expansion vessel to return

It is difficult to diagnose the F75 fault and it is easy to overlook other faults in boilers. If you are unsure, contact a Gas Safe engineer or have them take a look during your Vaillant boiler service.

Vaillant F75 is the most frequent fault code for ecoTEC Vaillant boilers. This is one of the most frustrating error codes because it can have multiple causes and may require a number of solutions to get your boiler back up and running.

Officially, the Vaillant error F75 refers to the fact that the pump cannot detect a pressure change when it starts up. The boiler is unable to detect pressure changes when the pump is operating. This means that either the pressure sensor, or the pump itself is malfunctioning. Because they have the expertise and training to deal with Vaillant fault codes, a Gas Safe engineer can be of assistance.

Central heating pump

The central heating pump is one of the most important parts of your Vaillant boiler. It is what circulates the water around your radiators. if this is broken then no water will be flowing around your central heating system. A new central heating pump can be expensive, so consider how much a new boiler costs before making any decisions.

What are the Common Causes of a Vaillant F75 Fault code?

A pump manufactured by Wilo was featured in the original Vaillant ecoTEC boilers. It is now well-known that these pumps are prone to failure. They are particularly susceptible to leaking and splitting. Grundfos is a manufacturer of modern ecoTEC boilers. These pumps are more durable and long-lasting than the ones made by Wilo and have a lower failure rate. If you have an ecoTEC boiler older than ten years, the pump is likely to be the problem.

The pressure sensor has gone through three revisions since 2005 when the Vaillant ecoTEC boiler was launched. Vaillant realized that the original sensor had a high failure rate and developed a replacement. This was because the sensor was blocked quickly with sludge, debris and other substances. It was unable to detect pressure changes as the pump operated. This would result in a boiler-related F75 error code.

Two things could cause the sensor to become blocked. It could be due to carbon and debris building up in the filtration system or the boiler system not being properly cleaned and maintained during its installation.

How can the Vaillant F75 error code be fixed?

There are many reasons the Vaillant F75 error code might appear. It is important to take a systematic approach to its repair.

  • It is important to determine if the fault is caused by the pressure sensor or the pump. This can be done by listening to the boiler’s sound when it is turned on and trying to function.
  • You can reset the boiler by pressing the button marked with a cross-flame symbol (the lockout key) and then turning on the heating or running hot water tap if there is a need for heat.
  • The pump should be running for several seconds approximately every twenty seconds. This is a good sign that it is working properly. The pump will make a low rumbling noise. This is likely to be the fault code Vaillant F75 if you can hear it.
  • If the pump is not making a loud rumbling sound when it runs, the problem may be with the pump. To replace the faulty pump, a Gas Safe engineer will be called to inspect the boiler.
  • It is possible to fix the problem if the pressure sensor is the culprit. First, remove the pressure sensor from the tank. Next, clean out the water-block. Pressure sensors are very affordable so you can replace them instead of trying to clean the old one.

Is F75 the Only Vaillant Error code?

F75 is one of many error codes that may be displayed on a Vaillant boiler. There may be an error code if your boiler is having trouble. If you do notice an error code, please tell us what it is when you call us. This will allow us to plan the correct type of repair for your system when we visit you. We are a team made up of experienced, highly-trained boiler engineers. You can feel confident in our ability to fix your boiler.

What if I could fix this fault code myself?

You should not attempt to fix the F75 Vaillant fault code yourself. You should contact our Gas Safe registered engineers for assistance.

How can I reset my boiler?

The reset process for most boilers, even those made by Vaillant is quite simple. You simply need to press the reset button on a Vaillant boiler which is usually located near the boiler’s display. Hold it for about 3-5 seconds. This should clear any error codes from the boiler’s display.

A boiler model may allow a reset to take place with a knob rather than a button. You would need to move the knob to the “reset” position and then hold it there for at least 3-5 seconds.

Resetting a boiler won’t solve the problem that caused it lock up. Resetting a boiler should be done only after the root cause of the problem has been resolved.

How can I check the pressure in my Vaillant boiler

The type of boiler you have will determine whether the pressure gauge is analogue or digital. If the pressure gauge is digital, you will need to see where the needle points on the dial. This ranges from 0 to 4 bar. If it is the latter, (i.e. If it’s the latter (i.e., a digital gauge), the pressure reading will be displayed in bars on the display.

Ideal operating conditions for your boiler are around 1-1.5 bars

FAQ’S

How can I differentiate between a faulty pressure sensor and a malfunctioning pump when troubleshooting the Vaillant F75 error code?

Differentiating between a faulty pressure sensor and a malfunctioning pump when trying to fix the Vaillant F75 error code requires a systematic approach. You can listen to the boiler’s sound when it is turned on to determine if the pump is working properly.

A working pump should run for several seconds approximately every twenty seconds and produce a low rumbling noise. If the pump isn’t making this sound, it may be the source of the fault. However, if the pump seems to be operating correctly, the issue could lie with the pressure sensor.

Are there any servicing measures that can reduce the likelihood of encountering the Vaillant F75 fault code, such as regular system cleaning or pump inspections?

Certain maintenance measures can indeed help reduce the likelihood of encountering the Vaillant F75 fault code. Regular system cleaning and servicing, especially during installation, can prevent issues related to carbon buildup or debris accumulation in the filtration system. Additionally, periodic pump inspections can help detect any potential issues early on, allowing for timely repairs or replacements before they turn into more significant problems.

Is there any recourse or support available from Vaillant for older ecoTEC boilers with known issues like the Wilo pumps, especially if the warranty has expired?

For older ecoTEC boilers with known issues like the Wilo pumps, especially if the warranty has expired, there may be limited recourse or support available from Vaillant. However, it’s worth exploring options such as contacting Vaillant’s customer service or seeking assistance from certified technicians who may offer aftermarket solutions or replacements for problematic components.

Related Articles

Boiler Advice

F29 Vaillant Fault Code Meaning And How To Fix It

25 April 2024

If you’re facing the Vaillant f29 fault code, you’re dealing with a flame failure that prevents y...

Boiler Advice

Best Combi Boiler 2024 and Top 7 Combi Boilers in the UK

15 April 2024

Which is the best combi boiler to buy in 2024? Choosing the right combi boiler depends significan...

Boiler Advice

Can I Get Boiler Finance With Bad Credit? Solutions for Poor Credit Scores

20 March 2024

Boiler finance bad credit might seem like a closed door, yet there are paths still open to you. T...